Clean Agent Cylinder Refilling & Recharge

Repair, refill and recharge of FM-200 (HFC-227ea) and Novec 1230 suppression cylinders through a UL/ULC-listed facility — with a 24-hour emergency recharge service.

AT A GLANCE
Agents
HFC-227ea (FM-200), Novec 1230
Facility
UL/ULC-listed recycling & refilling
Emergency
24-hour cylinder recharge
Brands
Kidde, Fike, Ansul, Siemens & more
Also
We buy & sell clean agents
WHAT WE OFFER

Get your suppression system back in service — fast

After a discharge, or when a cylinder loses pressure, your critical room is unprotected until the system is recharged. Fire Cloud repairs, refills and recharges FM-200 (HFC-227ea) and Novec 1230 cylinders through a UL/ULC-listed clean-agent recycling and refilling facility.

We offer a 24-hour emergency recharge service, and we buy and sell clean agents.

Clean agent recharge station filling an FM-200 cylinder
Services
  • Recharge after a discharge or accidental release
  • Repair of low-pressure or leaking cylinders
  • Clean-agent recovery and recycling
  • Refill and recharge of HFC-227ea (FM-200) and Novec 1230
  • 24-hour emergency cylinder recharge
  • Purchase and sale of clean agents
MANUFACTURERS WE SERVICE

Cylinders from all major suppression brands

KiddeChemetronFenwalSevoAnsulFireFlexFikeMinimaxSiemensFireTraceSea-Fire
OUR PROCESS

From collection to reinstallation

  1. Collection and inspectionCylinders are collected from site and inspected, with the agent, weight and pressure recorded.
  2. Agent recoveryAny remaining agent is recovered for recycling — nothing is vented to atmosphere.
  3. Cylinder and valve serviceValves, seals and gauges are serviced or replaced as required.
  4. Refill and superpressurisationThe cylinder is refilled by weight and superpressurised with nitrogen to the manufacturer’s specification.
  5. Leak check and labellingEach cylinder is leak-checked, labelled and documented.
  6. ReinstallationCylinders are reinstalled and the system is checked by our engineers.
System discharged?

Call us now for a 24-hour emergency recharge and get your critical room protected again.

MORE SPECIALIST TESTS

Other tests we carry out in-house

FM-200 Room Integrity Test
Door-fan testing that proves your enclosure holds the clean agent for the full retention time.
View test →
Foam Conductivity Test
Confirms your AFFF proportioning delivers the correct 3% or 6% concentration.
View test →
Fire Pump Performance Test
Churn and annual flow testing to NFPA 25 with a documented pump curve.
View test →
Need this test carried out?
Our engineers can schedule a visit anywhere in Qatar — 24/7 for urgent cases.
Call +974 7070 8830WhatsApp
BOOK A TEST

Book your test with our engineers

Tell us about the system and location. We will confirm the scope, schedule and price.

Office
Building 194, Street 105, Zone 57, Doha, Qatar
Availability
24/7 emergency response, 365 days a year
Chat on WhatsApp