ACTIVE FIRE PROTECTION

Firefighting Systems

Fire pump sets, sprinkler, hydrant, hose reel, standpipe, deluge and pre-action systems — engineered with in-house hydraulic calculations and installed to NFPA and Civil Defence requirements.

AT A GLANCE
Standards
NFPA 13 · 14 · 15 · 20 · 24
Systems
Sprinkler, standpipe, hydrant, hose reel, deluge, pre-action
Fire pumps
Electric, diesel and jockey pump sets
Ideal for
Towers, warehouses, hotels, industrial plants
Deliverable
Hydraulic calculations, shop drawings, test certificates
OVERVIEW

Water-based protection, sized by calculation

Sprinklers, standpipes and hydrants only perform if the water arrives at the right pressure and flow. That depends on correct hazard classification, pipe sizing and a fire pump selected for the real demand of the building.

We carry out hydraulic calculations in-house for every system, coordinate shop drawings with the other services, and install with UL-listed and FM-approved equipment — so the system passes its tests the first time and keeps performing for years.

What you receive
  • Hydraulic calculations for every system
  • Coordinated shop drawings and isometrics
  • UL-listed and FM-approved pipes, valves and devices
  • Flushing and hydrostatic test certificates
  • Pump acceptance test with a documented curve
WHAT WE COVER

Systems we design and install

Fire pump sets
Electric, diesel and jockey pumps with controllers, fuel systems and test headers to NFPA 20.
Automatic sprinklers
Wet, dry and ESFR systems for offices, car parks, warehouses and high-piled storage.
Standpipes & hose reels
Standpipe risers, landing valves and hose reel cabinets to NFPA 14.
Hydrants & fire mains
External hydrant networks and underground fire mains to NFPA 24.
Deluge & water spray
Open-head systems for transformers, fuel tanks and high-hazard process areas.
Pre-action systems
Detection-controlled sprinklers for data centres, archives and areas where accidental discharge must be avoided.
HOW WE DELIVER

Engineered, installed and tested by one team

  1. Hydraulic designHazard classification, design density and in-house hydraulic calculations.
  2. Shop drawings & approvalsCoordinated drawings and submittals taken through consultant and QCDD approval.
  3. InstallationPipework, hangers, valves and the pump room installed under engineer supervision.
  4. TestingFlushing, hydrostatic testing, alarm valve trip tests and pump acceptance testing.
  5. HandoverCivil Defence inspection, as-built drawings, test certificates and O&M manuals.
Standpipe landing valves and fire hydrant piping
Pump not reaching its rated pressure?

We carry out churn and flow performance tests to NFPA 25 and plot the actual pump curve against its rating.

Fire pump test
RELATED SERVICES

More from one accountable team

Fire Alarm & Detection
Addressable and conventional fire alarm, VESDA, gas detection and voice evacuation to NFPA 72.
View service →
Fire Suppression
FM-200, Novec 1230, CO₂, foam, aerosol and UL 300 kitchen systems.
View service →
Maintenance & AMC
Planned maintenance to NFPA 25, certification support and 24/7 emergency response.
View service →
Need hydraulic calculations or a firefighting design?
Send us your drawings or tender documents and our engineers will come back with a proposal.
Call +974 7070 8830WhatsApp
GET A QUOTE

Let’s talk about your project

Share your drawings, scope or tender documents. Our engineers will confirm the scope, programme and price.

Office
Building 194, Street 105, Zone 57, Doha, Qatar
Availability
24/7 emergency response, 365 days a year
Chat on WhatsApp